2120








ELECTRONIC HYGROTHERM
ETF 012
The electronic hygrotherm simultaneously monitors the temperature and humidity in enclosures and control cabinets. Condensation is prevented by switching heating and fans on or off as needed.
The version with an external sensor can be installed anywhere in the control cabinet and enables precise measurement.
The version with an external sensor can be installed anywhere in the control cabinet and enables precise measurement.
- Adjustable temperature and humidity
- Wide voltage range
- High switch performance
- Operating temperature as low as -40 °C
- Optical status indicator
Downloads
Overview Technical Data
2 K (±1 K tolerance) at +25 °C (+77 °F), 50% RH
4% RH (±1% tolerance) at +25 °C (+77 °F), 50% RH
~ 5 s
change-over contact (relay)
VDE: NO/NC > 15,000 cycles
UL: NO/NC > 30,000 cycles
UL: NO/NC > 30,000 cycles
240 VAC, 10 (1.6) A
60 VDC, 0.6A¹
60 VDC, 0.6A¹
AC 30 A for 10 s
LED
5-pole terminal, clamping torque 0.5Nm max.:
rigid/stranded² wire 2.5mm² (AWG 14)
rigid/stranded² wire 2.5mm² (AWG 14)
clip for 35mm DIN rail, EN 60715
plastic according to UL94 V-0, light grey
77 x 60 x 43 mm
~ 0,2 kg
vertical
-40 to +60 °C (-40 to +140 °F)
< 90% RH (non-condensing)
IP20
VDE, UL File No. E164102, EAC
¹ not UL confirmed
² When connecting with stranded wires, wire end ferrules must be used.
Product variants
Note: For the data of the cable version 01231.x-yy please refer to the data sheet
Summary of your request
Art. No. | Connection casing | Casing | Productname | Series | Heating element | Heater body | Model | Axial fan | Operating voltage |
Operating voltage max. |
Operating voltage min. |
Voltage type | Frequency | Heating capacity |
Inrush current max. |
Surface temperature |
Rec. pre-fuse T (time-delay) |
Connection | Connection PE | Air outlet temperature | Switch-off temperature | Switch-off temperature 2 | Switch-on temperature | Switch-on temperature 2 | Drilling template | Operating temperature |
Flow rate, free flow |
Flow rate, with filter |
Setting range | Setting range 2 |
Current consumption |
Nominal current of socket |
Power consumption |
Average noise level | Enclosure cut-out | Enclosure cut-out | Storage temperature | Storage humidity | Ambient temperature | Operating humidity | Speed |
Switching capacity max. |
Switching current min. |
Load resistance (external) | External Sensor | Measuring range | Measuring range 2 | Note | Note 2 | Note 3 | Note 4 | Reaction time | Contact type | Service life | Operation indicator |
Control contact - Signal current |
Electrical protection | Switch | Socket | Material | Material sealing | Air permeability | Mounting | Air intake/Air outlet | Filter material | Measuring signal |
Switch temperature difference |
Lamp type | Luminous flux | Light colour | Length / Depth | Width | Height | Diameter | Installation depth | Fitting position | Mounting frame | Weight | Sensor element | Protection class | Protection type | Protection type UL | VDE | UL | EAC | METRO | ATEX | Ex Protection type Gases | Ex Protection type Mine applications | Ex Protection type Dusts | Temperature class |
Temperature safety cut-out |
Accessory | Accessory 2 | Accessory 3 | Accessory 4 | Art. No. Accessory | Art. No. Accessory 2 | Art. No. Accessory 3 | Art. No. Accessory 4 | Catalogue Article | CAD |
---|
Everything from one source
Suitable Products
Heating
Prevent subnormal temperatures and condensation using enclosure heaters, either with or without fans.

Cooling
Achieve perfect enclosure cooling, even in systems tightly fitted with components, using filter fans and fans.

Accessories
We simplify thermal management for you with accessories such as sockets, components for passive ventilation and pressure equalisation devices.